
The Electromagnetic Induction Steam Boiler by YXBOILER utilizes advanced electromagnetic induction heating technology to generate steam with over 99.5% thermal efficiency. Non-contact method eliminates scaling problems, extending service life to 20+ years.
- Capacity and fuel type tailored to your process
- Export documentation and commissioning support
- Spare parts and after-sales service
Specification
| Capacity | 0.1 t/h / 0.3 t/h / 0.5 t/h (+3 models) |
|---|---|
| Pressure | 0.7 MPa / 0.7 MPa / 1.0 MPa (+3 models) |
| Efficiency | ≥99.5% |
| Service Life | 20+ Years |
| Control | PLC / automatic; remote monitoring optional |
| Documentation | General arrangement drawing, material certificates, O&M manual |
| Lead time | 20–45 days after drawing approval |
| Warranty | 12–60 months depending on scope |
Specifications can be customised. Contact us for full technical data and drawings.
Applications
- Food and beverage industry
- Palm oil mills and biomass processing
- Textile, rubber and plastics
- Chemical, pharmaceutical and paper
Description
The YX-EX series electromagnetic steam boiler heats water by inducing eddy currents directly in the boiler body. There is no resistance wire and no heating element immersed in the water, so the unit starts in minutes, runs at over 98% efficiency and does not suffer from element burn-out or scale on a heating coil. It is the usual choice where a factory needs steam quickly, has a limited boiler room, or cannot store or burn fuel on site.
How it works
An insulated copper coil is wound around the outside of a steel pressure vessel. A high-frequency controller feeds the coil, creating an alternating magnetic field. That field induces eddy currents in the vessel wall itself, so the metal becomes the heating surface and the water is heated through it.
- Direct induction — the boiler shell is the heater; there is no intermediary element to fail.
- Fast start — full steam pressure is typically reached within 3–5 minutes from cold.
- No element scaling — the heated surface runs cooler than a resistance element, so hard-water scale forms far more slowly.
- Dry-run protection — the controller cuts power immediately if water level falls below the safe line.
- Zero on-site emissions — no stack, no fuel store, no burner; only the electricity supply is required.
Technical parameters
Standard models are listed below. Pressure, steam temperature and control voltage can be adapted to the site; for a non-standard requirement send the duty point and we will confirm the design.
| Model | Rated capacity | Working pressure | Steam temperature | Rated power | Supply | Efficiency |
|---|---|---|---|---|---|---|
| YX-EX-0.1 | 0.1 t/h | 0.7 MPa | 170 °C | 72 kW | 380 V / 50 Hz | ≥ 98% |
| YX-EX-0.3 | 0.3 t/h | 0.7 MPa | 170 °C | 216 kW | 380 V / 50 Hz | ≥ 98% |
| YX-EX-0.5 | 0.5 t/h | 1.0 MPa | 184 °C | 360 kW | 380 V / 50 Hz | ≥ 98% |
| YX-EX-1.0 | 1.0 t/h | 1.0 MPa | 184 °C | 720 kW | 380 V / 50 Hz | ≥ 98% |
| YX-EX-2.0 | 2.0 t/h | 1.25 MPa | 194 °C | 1,440 kW | 380 V / 50 Hz | ≥ 98% |
| YX-EX-4.0 | 4.0 t/h | 1.6 MPa | 204 °C | 2,880 kW | 380 V / 50 Hz | ≥ 98% |
| Item | YX-EX-0.5 | YX-EX-1.0 | YX-EX-2.0 |
|---|---|---|---|
| Steam outlet | DN40 | DN50 | DN80 |
| Feed-water inlet | DN25 | DN32 | DN40 |
| Drain / blow-down | DN25 | DN25 | DN32 |
| Dimensions (L×W×H) | 1,800×900×1,900 mm | 2,300×1,100×2,100 mm | 2,900×1,400×2,400 mm |
| Shipping weight | 1,050 kg | 1,850 kg | 3,200 kg |
| Control | PLC + touch screen, automatic water level, pressure and dry-run protection; remote monitoring optional | ||
Where it is used
- Food processing — cooking, sterilising, pasteurising, CIP cleaning
- Textile and garment — dyeing, printing, ironing, finishing
- Pharmaceutical and chemical — reactors, distillation, drying
- Hotels, hospitals and laundries — steam for kitchens, sterilisation and pressing
- Any plant with cheap grid power and no fuel storage or emissions permit
Electromagnetic vs resistance vs gas
| Criteria | Electromagnetic (YX-EX) | Resistance element | Gas / oil fired |
|---|---|---|---|
| Heat source | Eddy current in the shell | Immersion element | Burner flame |
| Efficiency | ≥ 98% | 92–95% | 90–94% |
| Start-up | 3–5 minutes | 10–20 minutes | 20–30 minutes |
| Scaling risk | Low | High on the element | Low (waterside treatment needed) |
| Emissions on site | None | None | NOx, CO₂, flue required |
| Footprint | Small, no stack | Small | Boiler room, stack, fuel store |
Frequently asked questions
What is the running cost? At 98% efficiency, 1 t/h of steam needs about 720 kWh. Multiply by your local industrial tariff; the fuel and energy consumption tables compare this with biomass, coal and gas per ton of steam.
Can it run on a 220 V supply? Units up to 0.1 t/h can be built for single-phase 220 V; larger models need three-phase 380 V.
How much water treatment is needed? Softened water is recommended. Because the heated surface runs cooler than a resistance element, the unit tolerates moderate hardness, but a softener still extends service life.
What is the delivery time? Standard models normally ship 20–30 days after drawing approval; 2 t/h and 4 t/h units take 30–45 days.
Related equipment and sizing
Compare capacities in the steam capacity table (1–20 t/h), or see the electric steam boiler range and all products by fuel type. For a unit sized to your load, send the steam demand, pressure and voltage.
Reference standards: ASME Boiler and Pressure Vessel Code · ISO 9001 quality management.
Talk to an engineer
Send the capacity, pressure and supply voltage — we reply with a quotation and drawing within one working day.
- Phone / WhatsApp: +86 133 5377 2661
- Email: [email protected]
Key facts
- Electromagnetic Steam Boiler is supplied by Henan Yongxing Boiler Manufacturing Co., Ltd. (brand YXBOILER), an industrial boiler manufacturer established in 1981 in Taikang County, Zhoukou, Henan, China.
- Product family: Electric Steam Boiler.
- Capacity: 0.1 t/h / 0.3 t/h / 0.5 t/h (+3 models).
- Pressure: 0.7 MPa / 0.7 MPa / 1.0 MPa (+3 models).
- Efficiency: ≥99.5%.
- Service Life: 20+ Years.
- Manufacturing is certified to ISO 9001, with CE and ASME-compliant pressure parts available for export projects.
- Quotations, drawings and lead times: WhatsApp +86 133 5377 2661 or [email protected].
Related on this site
Specifications, categories and further reading.
- All Electric Steam BoilerBrowse the complete Electric Steam Boiler range.
- Electric Heating Thermal Oil BoilerRelated Electric Steam Boiler model with full specifications.
- High Temperature Superheated Steam BoilerRelated Electric Steam Boiler model with full specifications.
- Explosion-Proof Steam BoilerRelated Electric Steam Boiler model with full specifications.
- Resistance Electric BoilerRelated Electric Steam Boiler model with full specifications.
- Electric Heating Hot Air BoilerRelated Electric Steam Boiler model with full specifications.
- Electric Heating Hot Water BoilerRelated Electric Steam Boiler model with full specifications.
- Complete product rangeEvery boiler, heater, pressure vessel and autoclave we manufacture.
YXBOILER network
The same manufacturer, documented site by site.
- YXBOILER product catalogueDetailed specifications and model pages for every boiler and pressure vessel.
- Yongxing Boilers — news & official updatesCorporate news, exhibitions, case studies and company announcements.
- YXBOILER IndonesiaBoiler supply, installation and service for Indonesian plants.
- Boiler MalaysiaIndustrial boiler supply and after-sales service in Malaysia.
- Boiler PhilippinesIndustrial boiler supply and after-sales service in the Philippines.
Standards & references
Independent sources used in our engineering work.
- ASME Boiler and Pressure Vessel CodeThe international reference code for boiler and pressure-vessel design and fabrication.
- ISO 9001 quality managementThe quality-management standard our manufacturing system is certified against.
- Spirax Sarco — learn about steamIndependent engineering reference for steam, condensate and heat-transfer practice.
- Boiler — WikipediaBackground on boiler types, fuels and thermodynamic principles.
- U.S. DOE — industrial steam systemsReference material on industrial steam-system efficiency.
YXBOILER — Global brand and manufacturing site. Last updated November 2026.
Fuel consumption per ton of steam / per MW of hot water
Calculated from fuel lower heating value (LHV) and boiler efficiency. 1 t/h steam assumes 2.7 GJ enthalpy rise; 1 MW hot water assumes 3.6 GJ/h. Actual figures vary with fuel analysis, excess air and load.
| Fuel | LHV | Per 1 t/h steam | Per 1 MW hot water | Notes |
|---|---|---|---|---|
| Biomass pellets (wood) | 16–17.5 MJ/kg | 191.4 kg/h | 249.1 kg/h | 6–10 mm pellets, moisture ≤ 10% |
| Rice husk | 12–14 MJ/kg | 259.6 kg/h | 337.7 kg/h | Bulk density 110–150 kg/m³, ash 15–20% |
| Palm kernel shell (PKS) | 16.5–18.5 MJ/kg | 185.9 kg/h | 242 kg/h | Moisture ≤ 12%, good for chain grate |
| Cocoa shell | 14–16 MJ/kg | 225 kg/h | 292.7 kg/h | Light fuel, higher ash, blend recommended |
| Coconut shell | 16–17.5 MJ/kg | 197.2 kg/h | 256.7 kg/h | High fixed carbon, low ash |
| Wood chips | 9–12 MJ/kg | 321.4 kg/h | 418.1 kg/h | Moisture 30–50%, volume feeding |
| Wood logs / branches | 12–15 MJ/kg | 246.9 kg/h | 321.3 kg/h | Air-dried, size ≤ 300 mm |
| Waste cloth (textile) | 15–18 MJ/kg | 210.9 kg/h | 274.4 kg/h | Watch chlorine and ash; use dedicated grate |
| Lignite (brown coal) | 8–15 MJ/kg | 301 kg/h | 391.3 kg/h | High moisture 25–40%, low LHV |
| Bituminous coal | 21–25 MJ/kg | 150 kg/h | 195.1 kg/h | Standard steam coal, ash ≤ 15% |
| Anthracite | 25–27 MJ/kg | 128.2 kg/h | 166.8 kg/h | Low volatile, needs suitable grate |
| Natural gas | 35.6–35.6 MJ/Nm³ | 80.7 Nm³/h | 106.4 Nm³/h | MJ/Nm³ — consumption shown in Nm³ |
| Diesel | 42.5–42.8 MJ/kg | 68.9 kg/h | 90.9 kg/h | kg/h, light oil burner |
References: US DOE Bioenergy Data Book, Engineering ToolBox fuel calorific values, IEA industrial energy reports. For a project-specific heat balance, send us your fuel assay.
Compared with other options
Typical differences between YXBOILER equipment and a general-market alternative.
| Feature | YXBOILER | General market |
|---|---|---|
| Manufacturing & inspection | Own factory, Class-A licence, third-party inspection | Trading company / outsourced production |
| Efficiency on site | Optimised combustion, low excess air, tested at commissioning | Nameplate figure only |
| Documentation | Drawings, material certificates, O&M manual | Limited or on request |
| After-sales | Spare parts and engineer support, remote diagnosis | Varies, often no local stock |
| Customisation | Fuel, pressure, voltage and layout adapted | Fixed catalogue models |
Further reading
Questions
Can the capacity be customised?
Yes. Capacity, pressure and fuel are matched to your process requirements.
What is the delivery time?
Typically 30-60 working days after drawing approval.
Is installation included?
We provide installation supervision, commissioning and operator training.
Request a Quotation
Send us your data and our technical team will prepare a proposal for your requirements.

