[email protected] +86 133 5377 2661 Taikang, Zhoukou, Henan, China
YXBOILER

Electromagnetic Steam Boiler

Electromagnetic Steam Boiler

The Electromagnetic Induction Steam Boiler by YXBOILER utilizes advanced electromagnetic induction heating technology to generate steam with over 99.5% thermal efficiency. Non-contact method eliminates scaling problems, extending service life to 20+ years.

  • Capacity and fuel type tailored to your process
  • Export documentation and commissioning support
  • Spare parts and after-sales service

Specification

Capacity0.1 t/h / 0.3 t/h / 0.5 t/h (+3 models)
Pressure0.7 MPa / 0.7 MPa / 1.0 MPa (+3 models)
Efficiency≥99.5%
Service Life20+ Years
ControlPLC / automatic; remote monitoring optional
DocumentationGeneral arrangement drawing, material certificates, O&M manual
Lead time20–45 days after drawing approval
Warranty12–60 months depending on scope

Specifications can be customised. Contact us for full technical data and drawings.

Applications

  • Food and beverage industry
  • Palm oil mills and biomass processing
  • Textile, rubber and plastics
  • Chemical, pharmaceutical and paper

Description

The YX-EX series electromagnetic steam boiler heats water by inducing eddy currents directly in the boiler body. There is no resistance wire and no heating element immersed in the water, so the unit starts in minutes, runs at over 98% efficiency and does not suffer from element burn-out or scale on a heating coil. It is the usual choice where a factory needs steam quickly, has a limited boiler room, or cannot store or burn fuel on site.

How it works

An insulated copper coil is wound around the outside of a steel pressure vessel. A high-frequency controller feeds the coil, creating an alternating magnetic field. That field induces eddy currents in the vessel wall itself, so the metal becomes the heating surface and the water is heated through it.

  • Direct induction — the boiler shell is the heater; there is no intermediary element to fail.
  • Fast start — full steam pressure is typically reached within 3–5 minutes from cold.
  • No element scaling — the heated surface runs cooler than a resistance element, so hard-water scale forms far more slowly.
  • Dry-run protection — the controller cuts power immediately if water level falls below the safe line.
  • Zero on-site emissions — no stack, no fuel store, no burner; only the electricity supply is required.

Technical parameters

Standard models are listed below. Pressure, steam temperature and control voltage can be adapted to the site; for a non-standard requirement send the duty point and we will confirm the design.

Model Rated capacity Working pressure Steam temperature Rated power Supply Efficiency
YX-EX-0.1 0.1 t/h 0.7 MPa 170 °C 72 kW 380 V / 50 Hz ≥ 98%
YX-EX-0.3 0.3 t/h 0.7 MPa 170 °C 216 kW 380 V / 50 Hz ≥ 98%
YX-EX-0.5 0.5 t/h 1.0 MPa 184 °C 360 kW 380 V / 50 Hz ≥ 98%
YX-EX-1.0 1.0 t/h 1.0 MPa 184 °C 720 kW 380 V / 50 Hz ≥ 98%
YX-EX-2.0 2.0 t/h 1.25 MPa 194 °C 1,440 kW 380 V / 50 Hz ≥ 98%
YX-EX-4.0 4.0 t/h 1.6 MPa 204 °C 2,880 kW 380 V / 50 Hz ≥ 98%
Item YX-EX-0.5 YX-EX-1.0 YX-EX-2.0
Steam outlet DN40 DN50 DN80
Feed-water inlet DN25 DN32 DN40
Drain / blow-down DN25 DN25 DN32
Dimensions (L×W×H) 1,800×900×1,900 mm 2,300×1,100×2,100 mm 2,900×1,400×2,400 mm
Shipping weight 1,050 kg 1,850 kg 3,200 kg
Control PLC + touch screen, automatic water level, pressure and dry-run protection; remote monitoring optional

Where it is used

  • Food processing — cooking, sterilising, pasteurising, CIP cleaning
  • Textile and garment — dyeing, printing, ironing, finishing
  • Pharmaceutical and chemical — reactors, distillation, drying
  • Hotels, hospitals and laundries — steam for kitchens, sterilisation and pressing
  • Any plant with cheap grid power and no fuel storage or emissions permit

Electromagnetic vs resistance vs gas

Criteria Electromagnetic (YX-EX) Resistance element Gas / oil fired
Heat source Eddy current in the shell Immersion element Burner flame
Efficiency ≥ 98% 92–95% 90–94%
Start-up 3–5 minutes 10–20 minutes 20–30 minutes
Scaling risk Low High on the element Low (waterside treatment needed)
Emissions on site None None NOx, CO₂, flue required
Footprint Small, no stack Small Boiler room, stack, fuel store

Frequently asked questions

What is the running cost? At 98% efficiency, 1 t/h of steam needs about 720 kWh. Multiply by your local industrial tariff; the fuel and energy consumption tables compare this with biomass, coal and gas per ton of steam.

Can it run on a 220 V supply? Units up to 0.1 t/h can be built for single-phase 220 V; larger models need three-phase 380 V.

How much water treatment is needed? Softened water is recommended. Because the heated surface runs cooler than a resistance element, the unit tolerates moderate hardness, but a softener still extends service life.

What is the delivery time? Standard models normally ship 20–30 days after drawing approval; 2 t/h and 4 t/h units take 30–45 days.

Related equipment and sizing

Compare capacities in the steam capacity table (1–20 t/h), or see the electric steam boiler range and all products by fuel type. For a unit sized to your load, send the steam demand, pressure and voltage.

Reference standards: ASME Boiler and Pressure Vessel Code · ISO 9001 quality management.

Talk to an engineer

Send the capacity, pressure and supply voltage — we reply with a quotation and drawing within one working day.

Key facts

  • Electromagnetic Steam Boiler is supplied by Henan Yongxing Boiler Manufacturing Co., Ltd. (brand YXBOILER), an industrial boiler manufacturer established in 1981 in Taikang County, Zhoukou, Henan, China.
  • Product family: Electric Steam Boiler.
  • Capacity: 0.1 t/h / 0.3 t/h / 0.5 t/h (+3 models).
  • Pressure: 0.7 MPa / 0.7 MPa / 1.0 MPa (+3 models).
  • Efficiency: ≥99.5%.
  • Service Life: 20+ Years.
  • Manufacturing is certified to ISO 9001, with CE and ASME-compliant pressure parts available for export projects.
  • Quotations, drawings and lead times: WhatsApp +86 133 5377 2661 or [email protected].

Related on this site

Specifications, categories and further reading.

YXBOILER network

The same manufacturer, documented site by site.

Standards & references

Independent sources used in our engineering work.

YXBOILER — Global brand and manufacturing site. Last updated November 2026.

Fuel consumption per ton of steam / per MW of hot water

Calculated from fuel lower heating value (LHV) and boiler efficiency. 1 t/h steam assumes 2.7 GJ enthalpy rise; 1 MW hot water assumes 3.6 GJ/h. Actual figures vary with fuel analysis, excess air and load.

FuelLHVPer 1 t/h steamPer 1 MW hot waterNotes
Biomass pellets (wood)16–17.5 MJ/kg191.4 kg/h249.1 kg/h6–10 mm pellets, moisture ≤ 10%
Rice husk12–14 MJ/kg259.6 kg/h337.7 kg/hBulk density 110–150 kg/m³, ash 15–20%
Palm kernel shell (PKS)16.5–18.5 MJ/kg185.9 kg/h242 kg/hMoisture ≤ 12%, good for chain grate
Cocoa shell14–16 MJ/kg225 kg/h292.7 kg/hLight fuel, higher ash, blend recommended
Coconut shell16–17.5 MJ/kg197.2 kg/h256.7 kg/hHigh fixed carbon, low ash
Wood chips9–12 MJ/kg321.4 kg/h418.1 kg/hMoisture 30–50%, volume feeding
Wood logs / branches12–15 MJ/kg246.9 kg/h321.3 kg/hAir-dried, size ≤ 300 mm
Waste cloth (textile)15–18 MJ/kg210.9 kg/h274.4 kg/hWatch chlorine and ash; use dedicated grate
Lignite (brown coal)8–15 MJ/kg301 kg/h391.3 kg/hHigh moisture 25–40%, low LHV
Bituminous coal21–25 MJ/kg150 kg/h195.1 kg/hStandard steam coal, ash ≤ 15%
Anthracite25–27 MJ/kg128.2 kg/h166.8 kg/hLow volatile, needs suitable grate
Natural gas35.6–35.6 MJ/Nm³80.7 Nm³/h106.4 Nm³/hMJ/Nm³ — consumption shown in Nm³
Diesel42.5–42.8 MJ/kg68.9 kg/h90.9 kg/hkg/h, light oil burner

References: US DOE Bioenergy Data Book, Engineering ToolBox fuel calorific values, IEA industrial energy reports. For a project-specific heat balance, send us your fuel assay.

Compared with other options

Typical differences between YXBOILER equipment and a general-market alternative.

FeatureYXBOILERGeneral market
Manufacturing & inspectionOwn factory, Class-A licence, third-party inspectionTrading company / outsourced production
Efficiency on siteOptimised combustion, low excess air, tested at commissioningNameplate figure only
DocumentationDrawings, material certificates, O&M manualLimited or on request
After-salesSpare parts and engineer support, remote diagnosisVaries, often no local stock
CustomisationFuel, pressure, voltage and layout adaptedFixed catalogue models

Questions

Can the capacity be customised?

Yes. Capacity, pressure and fuel are matched to your process requirements.

What is the delivery time?

Typically 30-60 working days after drawing approval.

Is installation included?

We provide installation supervision, commissioning and operator training.

Request a Quotation

Send us your data and our technical team will prepare a proposal for your requirements.

Kami membalas dalam satu hari kerja. Data hanya digunakan untuk menanggapi permintaan Anda.

Chat on WhatsApp
WhatsApp Email Inquiry
YXBOILER
YXBOILER
Taikang County, Zhoukou, Henan, China
WhatsApp +86 133 5377 2661 · [email protected]
https://www.yxboiler.com/
Electromagnetic Steam Boiler
2026-11-25 · YXBOILER · https://www.yxboiler.com/